Suswe SU-600 VSD keypad simulator
SU-600 VSD keypad simulator
Practise programming the SU600A drive before you touch the real one. Use the six keys and the speed knob exactly as on the drive. Settings are taken from the SU-600 manual.
SU600A-2R2G1-B2.2 kW · 1φ 230 V → 3φ 380 V
FWDHz
REVA
ALMV
Drive output
How the keys work
- PRG steps the screens: run display → F parameters → d monitor values → back. While viewing or editing a value, PRG backs out without saving.
- ▲ / ▼ in a list step through codes. Hold to scroll; it rolls into the next group.
- ENT opens a value. While editing, RUN moves the flashing digit, ▲ / ▼ change it. ENT saves and moves to the next code.
- On the run display, ▲ / ▼ edit the keypad's own speed setting. It only drives the motor when F0.03 = 1. With F0.03 = 0 the knob sets the speed.
- RUN / STOP start and stop when F0.02 = 0 (keypad). STOP/RST also clears a fault.
Settings changed from factory
All parameters
| Code | Name | Value | Factory | Range | Run |
|---|---|---|---|---|---|
Run column: ○ = can change while running, × = change only when stopped, ◆ = read only.
Activity
- Ready
Training simulator only. It follows the SU-600 operating manual and behaviour checked on a real drive, but it is not a substitute for the manual or for qualified installation. Questions: Southern Technology Ltd, 03 389 9258, southerntech.co.nz